| Type | WC2SU-09 | WC2SU-12 | WC2SU-18 | WC2SU-25 | WC2SU-32 | WC2SU-40 | WC2SU-50 | WC2SU-65 | WC2SU-80 | WC2SU-95 | |
| Main circuit characteristic | |||||||||||
| Poles | 3P | ||||||||||
| Main contact | 3NO | ||||||||||
| Rated insulation voltage(Ui)(V) | 690V | ||||||||||
| Rated operating voltage(Ue)(V) | AC220/230V; 380/400V; 660/690V | ||||||||||
| Rated thermal current(Ith), AC-1 | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | 100 | 125 | |
|
Rated operation current(le)(A)
| AC-3, 220/230V | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
| AC-4, 220/230V | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 | |
| AC-3, 380/400V | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 | |
| AC-4, 380/400V | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 | |
| AC-3, 660/690V | 6.6 | 8.9 | 12 | 18 | 22 | 34 | 39 | 42 | 49 | 49 | |
| AC-4,660/690V | 1.5 | 2 | 3.8 | 4.4 | 7.5 | 9 | 12 | 14 | 17.3 | 21.3 | |
|
Rated operational power(Pe)(kW)
| AC-3, 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
| AC-4, 220/230V | 0.6 | 1.1 | 1.5 | 2.2 | 3 | 5.5 | 6 | 7.5 | 11 | 14 | |
| AC-3, 380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
| AC-4, 380/400V | 1.5 | 2.2 | 3.3 | 4 | 5.4 | 7.5 | 11 | 15 | 18.5 | 22 | |
| AC-3, 660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 45 | |
| AC-4, 660/690V | 1.1 | 1.5 | 3 | 3.7 | 5.5 | 7.5 | 10 | 11 | 15 | 18.5 | |
| Mechanical life(×10⁴ times)
| 1000 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 600 | 600 | |
| Electrical life (x10⁴times)
| AC-3 | 100 | 100 | 100 | 100 | 80 | 60 | 60 | 60 | 60 | 60 |
| AC-4 | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 | |
| Frequency of operation (time/h)
| AC-3 | 1200 | 1200 | 1200 | 1200 | 600 | 600 | 600 | 600 | 600 | 600 |
| AC-4 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | |
| Control circuit characteristics
| |||||||||||
| Rated control voltage(Us)
| 50Hz | 24V,36V,48V,110V,230V,380V,415V,440V | |||||||||
| 50/60Hz | 24V,36V,48V,110V,230V,380V,415V,440V | ||||||||||
| Allowed control circuit voltage
| Operation | (85%~110%)Us | |||||||||
| Release | (20%~75%)Us | ||||||||||
Contactor is an automatic electromagnetic switch primarily used for frequently connecting or disconnecting AC/DC main circuits and high-capacity control circuits over long distances. It is widely used in electric drive systems, industrial automation control, building electrical systems, and other applications, serving as a core component for controlling loads such as motors, electric heaters, and lighting systems.
Core Functions:
1. Automatic On/Off: Magnetic force is generated by energizing an electromagnetic coil, driving the contacts to close or open.
2. Remote Control: Can be remotely operated via buttons, PLCs, relays, etc.
3. High Current Control: Capable of safely controlling high-current loads of hundreds of amperes.
4. Frequent Operation: Designed for frequent starts and stops, with a long lifespan (typically up to one million operations).
WC2SU Series ac contactors are used for controlling 3-phase motor circuits up to 69oV AC. These contactors are of the block type designwith 3 main poles. Built-in INO+INC auxiliary contact and surge suppression, resulting in installation time and cost savings.Compared with contactors using external surge suppressors, contactor products using builtin surge suppressors will have more reliableperformance and at the same time the surges are handled by the contactor itself and the surge never reaches the control circuit.